Application notes & Tutorial
Video Tutorial
Playlist
Application Notes
![](https://www.nuclearinstruments.eu/wp-content/uploads/2022/08/r5560hlink-300x300.jpg)
AN-008 R5560/SE DAQs horizontal interconnection
This document explains how to use the FLAG signals and fast horizontal link between DAQ. Each DAQ is directly connected to the DAQ on the
![](https://www.nuclearinstruments.eu/wp-content/uploads/2022/08/Single-end-diff-300x300.jpg)
AN-007 Single Ended to fully differential Conversion
Most of the SciCompiler supported board require fully differential signaling to correct operate. Differential signaling is a method for electrically transmitting information using two complementary
![](https://www.nuclearinstruments.eu/wp-content/uploads/2022/08/long-osc-300x300.jpg)
AN-006 Maximize the available memory on R5560/SE to obtain 16Ksamples per waves on 32 channels
This code example for SciCompiler demostrate how to use the new Oscilloscope Dual component to digitize waveforms from 32 channel with a memory depth of
![](https://www.nuclearinstruments.eu/wp-content/uploads/2022/08/v2740-gate-delay-300x300.jpg)
AN-005 Using hardware Gate and Delay of the V2495 / DT5495 in SciCompiler project
This application note will demonstrate how to use the hardware Gate and Delay of the X2495 board to shape a digital signal introducing a
![](https://www.nuclearinstruments.eu/wp-content/uploads/2022/08/multy-R5560-300x300.jpg)
AN-004 Synchronize multiple R5560 / R5560SE to for simultaneous sampling on multiple device
This application notes explains how to synchronize multiple R5560/R5560SE to extend the number of input channels sampled simultaneously. This document covers the following task: How
![](https://www.nuclearinstruments.eu/wp-content/uploads/2022/08/wave-digitizer-2-300x300.jpg)
AN-003 Wave dump using digitizer component
The digitizer block in SciCompiler works as a programmable size FIFO to store waveform. It is possible to define, compiling time, the maximum
![](https://www.nuclearinstruments.eu/wp-content/uploads/2021/12/ANSK001_Discriminator-1-300x267.png)
AN-002 Design a Fixed Threshold Discriminator with SciCompiler
This application note will show how to support a scientific application with an FPGA firmware, consisting of a signal discriminator with an arbitrary but
![](https://www.nuclearinstruments.eu/wp-content/uploads/2021/12/cp-300x300.png)
AN-001 Custom Packet data decode
SciCompiler allows to easy implement FIFO communication to transfer formatted data , like listo of energy, timecode, channels from FPGA to user computer in form